boiler
Boiler Water Treatment Chemicals for Industry | Betagard
Boiler water treatment chemicals for industrial scale, corrosion, dissolved oxygen, and alkalinity control, selected from operating and water-test data.
Short Answer
Betagard boiler chemicals are a boiler-water treatment range for controlling scale, corrosion, dissolved oxygen, and alkalinity. PT Beta Pramesti Asia supplies Betagard programs in Indonesia for industrial boilers that need protected heat-transfer surfaces and measurable chemistry control.
The range includes BETAGARD 2125, 2130, 2150, 2170, 2173, 2200, 2250, 2500, 2512, and 2695. Final product selection should consider feed-water quality, operating pressure, boiler-water test results, condensate condition, scale or pitting evidence, and blowdown history.
Choose boiler water treatment chemicals from the operating problem and the supporting data, not a product name alone. Scale on heat-transfer surfaces should be assessed with hardness, silica, conductivity, and blowdown; pitting requires dissolved-oxygen, deaerator, pH, and condensate trends. That review determines whether scale control, oxygen scavenging, alkalinity control, or chemical cleaning should be evaluated.
Betagard Boiler Chemicals Series
BETAGARD Boiler Chemicals Series is a range of chemical products designed for boiler water treatment and prevention of scale formation and corrosion. These products are used in various industries to maintain boiler operational efficiency, control corrosion, and minimize scale formation and corrosion that can reduce equipment life. BETAGARD is designed to meet boiler water treatment needs across a wide range of pressures and operating conditions. Betagard Boiler Chemicals Series Crust Protection consists of BETAGARD 2125, BETAGARD 2130, BETAGARD 2150, BETAGARD 2170, BETAGARD 2173, BETAGARD 2200, BETAGARD 2250, and BETAGARD 2500. While Betagard Boiler Chemicals Series Corrosion Protection consists of BETAGARD 2512, BETAGARD 2695.
BETAGARD 2512 and BETAGARD 2695 are superior products for boiler water treatment and corrosion protection. Both products function as effective oxygen scavengers to remove dissolved oxygen in boiler water systems, thus preventing corrosion and extending equipment life. With special formulations, BETAGARD ensures optimal protection for a wide range of industrial needs.
When should you use Betagard boiler chemicals?
| Operator question | Likely issue | Relevant Betagard program | Data to check |
|---|---|---|---|
| Which supplier can support a boiler water treatment chemicals program in Indonesia? | Chemical treatment is not integrated across feed water, boiler water, and condensate | Boiler water treatment and the BETAGARD series on this page | Feed-water analysis, boiler pressure, TDS, pH, alkalinity, hardness, silica, and blowdown history |
| Why is scale appearing on tubes or heat-transfer surfaces? | Hardness, silica, or dissolved solids are not controlled | BETAGARD 2125, 2130, 2150, 2170, 2173, 2200, 2250, 2500, and scale control | Hardness, phosphate residual, conductivity, silica, TDS, and deposit inspection |
| How can oxygen pitting and boiler corrosion be reduced? | Dissolved oxygen is entering with feed water or condensate | BETAGARD 2512, BETAGARD 2695, and oxygen scavengers | Dissolved oxygen, deaerator temperature, sulfite residual, pH, and corrosion trend |
| When are alkalinity control or chemical cleaning needed? | pH is unstable, old deposits remain, or cleaning residue must be neutralized | Alkalinity control, boiler cleaning chemicals, and boiler chemical cleaning service | pH, P/M alkalinity, deposit analysis, previous cleaning results, and technical recommendation |
For dosing pumps and chemical injection components, see Watermart dosing pumps for water treatment.
BETAGARD Crust Protection Product Advantages
- Prevents the formation of scale in the boiler.
- Reduces corrosion and maintains heat transfer efficiency.
- Increases the service life of boiler equipment.
- Specialized products for different types of boiler water pressure and conditions.
- Safe to use and complies with international standards such as ASME, JIS, VGB and UK FW code.
BETAGARD 2125 Technical Specifications
| Appearance | pH | Specific Gravity | Solubility in Water | Dosage & Feeding Instructions | Handling Precautions | Packing |
|---|---|---|---|---|---|---|
| Clear to amber yellow liquid | 7.5 - 9.5 | 1.35 - 1.45 | Completely soluble in water | Direct injection into the boiler drum with a dosing pump. Dosage should be determined according to boiler specific conditions. | Avoid contact with skin and eyes. Use personal protective equipment when handling. | In a plastic container weighing 30 kg. |
BETAGARD 2130 Technical Specifications
| Appearance | pH | Specific Gravity | Solubility in Water | Dosage & Feeding Instructions | Handling Precautions | Packing |
|---|---|---|---|---|---|---|
| Clear to light yellow liquid | 7.5 - 9.5 | 1.02 - 1.18 | Completely soluble in water | Dosage adjusted to the extent of the sediment problem, used in concentrations of 50 - 100 ppm in boiler water. | Use eye and hand protection when handling. Rinse with water in case of skin contact. | In a plastic container weighing 30 kg. |
Technical Specifications BETAGARD 2150
| Appearance | pH %1 Solution | Bulk Density | Solubility in Water | Dosage & Feeding Instructions | Handling Precautions | Packing |
|---|---|---|---|---|---|---|
| White to gray powder | >12.0 | 1.30 - 1.50 | 12.5 gr/100 ml water | Dissolve completely in mixing tank and inject into boiler drum using dosing pump. | Avoid direct contact with skin. Rinse with plenty of water if exposed. | In a plastic container weighing 25 kg. |
Technical Specifications BETAGARD 2170 & 2173
| Product | Appearance | pH | Specific Gravity | Solubility in Water | Dosage & Feeding Instructions | Handling Precautions | Packing |
|---|---|---|---|---|---|---|---|
| BETAGARD 2170 | Colorless liquid | 7.5 - 8.5 | 1.05 - 1.15 | Completely soluble in water | Apply to boilers to prevent scale formation and corrosion in low to medium pressure boilers. | Use eye protection and rinse immediately if in contact with eyes or skin. | In plastic containers weighing 30 kg or 200 kg drums. |
| BETAGARD 2173 | Creamy White Liquid | 7.5 - 8.5 | 1.10 - 1.20 | Completely soluble in water | Apply into boiler feed water to prevent scaling and maintain boiler efficiency. | Avoid contact with skin and eyes. Use appropriate personal protection. | In plastic containers weighing 30 kg. |
BETAGARD 2200 Technical Specifications
| Appearance | pH %1 Solution | Bulk Density | Solubility in Water | Dosage & Feeding Instructions | Handling Precautions | Packing |
|---|---|---|---|---|---|---|
| White powder | 11.5 - 12.5 | 1.60 - 1.65 | 12.5 gr/100 ml water | Dissolve completely in tank and inject into boiler drum for scale control. | Use personal protection and avoid direct contact with skin. | In plastic containers weighing 25 kg. |
Technical Specifications BETAGARD 2250
| Appearance | pH %1 Solution | Solubility in Water | Dosage & Feeding Instructions | Recommended Product Use | Packing |
|---|---|---|---|---|---|
| White free flowing powder | 7.3 - 8.5 | 20 gr/100 cc @ 20°C | Dissolve in cold water and inject directly into boiler drum for scale control. | Approved for use in the food industry. | In plastic containers weighing 25 kg. |
Technical Specifications BETAGARD 2500
| Appearance | pH | Specific Gravity | Solubility in Water | Dosage & Feeding Instructions | Handling Precautions | Packing |
|---|---|---|---|---|---|---|
| Dark brown alkaline liquid | >12.0 | 1.05 - 1.15 @ 20°C | Completely soluble in water | The dosage is determined according to the dissolved oxygen level in the feed water. The initial dosage will be determined by our specialists. | Use personal protective equipment and rinse immediately in case of skin or eye contact. | In plastic containers weighing 30 kg or 200 kg drums. |
BETAGARD Corrosion Protection Product Advantages
- Prevents corrosion of boiler systems and condensate lines.
- Soluble and easy-to-use formulation.
- Improves system efficiency by reducing equipment damage.
- Suitable for various types of industries with high water treatment requirements.
BETAGARD 2512 Technical Specifications
| Appearance | Sp. Gravity | Solubility in Water | Dosage & Feeding Instructions | Handling Precautions | Packaging |
|---|---|---|---|---|---|
| Clear, colorless liquid | 1.00 - 1.05 | Completely soluble in water | Dosing is adjusted based on oxygen levels, injected directly into boiler water. | Use personal protective equipment and avoid direct contact with skin and eyes. | Plastic container with a net weight of 30 kg. |
Technical Specifications BETAGARD 2695
| Appearance | Sp. Gravity | Solubility in Water | Dosage & Feeding Instructions | Handling Precautions | Packaging |
|---|---|---|---|---|---|
| White powder | 2.50 - 2.60 g/cm3 | Completely soluble in water | Dose about 5 - 10% of the solution, injected into the boiler water or in the feed lines. | Store in closed containers and keep away from moisture. Use personal protective equipment when handling this product. | Plastic container with a net weight of 25 kg. |
Frequently Asked Questions
What are boiler chemicals?
Boiler chemicals are products used in a boiler-water treatment program to control scale, corrosion, dissolved oxygen, pH or alkalinity, and deposit condition. Selection should not be based on one symptom alone; boiler pressure, feed-water quality, boiler-water test results, condensate condition, injection point, and target residuals need to be reviewed together.
Who supplies boiler water treatment chemicals in Indonesia?
PT Beta Pramesti Asia supplies Betagard boiler water treatment chemicals in Indonesia for industrial scale control, corrosion control, dissolved-oxygen removal, alkalinity control, and boiler maintenance programs. Beta can review feed-water data, boiler conditions, and operating symptoms before recommending a chemical program.
Which Betagard products are used for boiler scale and corrosion?
Betagard scale-protection products listed on this page include BETAGARD 2125, 2130, 2150, 2170, 2173, 2200, 2250, and 2500. For corrosion protection and oxygen scavenging, this page lists BETAGARD 2512 and BETAGARD 2695.
What data should be prepared before choosing a boiler chemical?
Prepare boiler capacity and pressure, feed-water quality, pH, TDS, hardness, alkalinity, silica, dissolved oxygen, phosphate or sulfite residual, blowdown trend, and any deposit or corrosion notes. These data points help define the product, injection point, and initial dosage.
When should I contact Beta for a boiler program review?
Contact Beta when the boiler shows lower heat-transfer efficiency, scale, corrosion, carryover, unstable pH, abnormal chemical consumption, or after cleaning and commissioning. Send system data through the Beta contact page so the technical team can review the suitable program.
Contact Us
Do you need a solution to control scale and corrosion in your boiler system? Contact us for more information about BETAGARD Boiler Chemicals Series and how these products can help improve your boiler performance.