WhatsApp

membrane

Industrial Reverse Osmosis System | Beta Pramesti Asia

Betaqua industrial RO units treat brackish water or seawater at 0.2–100 m³/h. Compare feed analysis, permeate targets, recovery, pretreatment and CIP.

Industrial Reverse Osmosis System | Beta Pramesti Asia

The Betaqua industrial reverse osmosis system from PT Beta Pramesti Asia treats brackish water or seawater to produce permeate for utilities and process use. Units on this page cover 0.2–100 m³/h; final sizing must follow feedwater analysis, permeate targets, recovery, pretreatment, and the concentrate-disposal route.

PT Beta Pramesti Asia supplies RO packages with cartridge filtration, pressure pumps, flow and pressure instruments, PLC control, autoflush, and model-dependent antiscalant dosing and CIP. Complete design data prevents a project from selecting equipment on nominal capacity alone.

The FilmTec RO/NF technical manual, revised February 2026 likewise treats feedwater analysis and pretreatment as design inputs. Catalogue capacity therefore needs to be read with the flow balance, recovery, permeate specification, scaling and fouling risk, and the limits of the membrane ultimately selected.

Data needed to select an industrial reverse osmosis system

Project dataWhy it matters
Permeate flow and operating hoursSets unit capacity and standby requirements
Feedwater analysisEstablishes pretreatment, recovery, and scaling or fouling risk
Required permeate qualityDetermines single-pass, double-pass, or polishing configuration
Concentrate-disposal routeConfirms that the water balance and reject stream are workable
Space, power, and controlsDefines layout, electrical load, instrumentation, and plant integration

What should an industrial RO quotation make explicit?

An industrial RO quotation should let the project team compare capacity, supply scope, utilities, and performance acceptance on the same basis. Ask for the design assumptions and exclusions in writing so a feedwater change or a tighter permeate target is not hidden behind one nominal-flow number.

Quotation sectionItems to state
Design basisWater analysis, temperature, feed flow, permeate flow, operating hours, recovery, product quality, and expected variability
Process scopePretreatment stages, pass and train count, membranes, pumps, vessels, cartridge filters, dosing, CIP, and concentrate route
Utilities and integrationPower, inlet pressure, service space, drains, chemical storage, piping materials, control signals, and battery limits
Performance acceptanceTest-feed condition, permeate parameters, flow, recovery, pressure, test duration, baseline data, and deviation handling
Post-handover operationManuals, training, initial spares, instrument calibration, monitoring schedule, CIP triggers, and support data

Evaluate RO antiscalant, membrane cleaning chemicals, and dosing pumps with the unit design. For membrane replacement and components, see industrial reverse osmosis membranes and systems at Watermart. Send the water analysis, capacity, and product-water target through the Beta contact page.

Which industrial RO system fits the project?

Feedwater type and the permeate specification determine whether the project evaluates BWRO, SWRO, single-pass, or double-pass treatment. Nominal capacity must still be checked against recovery, concentrate flow, train count, pretreatment, power, materials, and service space.

Project needConfiguration to evaluateChecks before selection
Brackish water or a saline raw-water sourceBrackish Water Reverse Osmosis (BWRO)Ion analysis, scaling risk, turbidity/SDI, permeate target, recovery, pressure, and concentrate route
SeawaterSeawater Reverse Osmosis (SWRO)Salinity, temperature, pretreatment, high pressure, materials, energy demand, and concentrate disposal
Tighter permeate specificationSingle pass with polishing or a double-pass configurationConductivity and product parameters at each stage, recovery balance, and any degassing or EDI/mixed-bed requirement
Critical or variable-flow operationMultiple trains, turndown, or standby capacityFlow profile, capacity with one train offline, controls, spares, and the cleaning plan

Seawater Reverse Osmosis 0.2–6 m³/h

SW 4-3E to SW 4-12E 0.2 m3/hour to 6 m3/hour (per unit)

SW 4-3E to SW 4-12E

SW 4-3E to SW 4-12E Capacity: 0.2 m3/hour to 6 m3/hour (per unit)

ModelMembrane QtyPermeate FlowrateFeed FlowrateFlowrate Conc.Pipe Size FeedPipe Size PermeatePipe Size Conc.Frame Size L (mm)Frame Size L (mm)Frame Size W (mm)Frame Size H (mm)Frame Size H’ (mm)Power (KW)
SW4-330.381.310.93111904127583018828303
SW4-440.51.470.97111904127583018828303
SW4-550.61.560.961111112127583018828303
SW4-660.751.871.121111112127583018828305.5
SW4-8812.51.51111320127583018828307.5
SW4-12121.53.752.2511117361275830188283015

Standard Features:

  • Multi-Stage Pump
  • 5 micron cartridge filter
  • AW PVC for low pressure piping
  • Stainless steel high pressure piping/hose
  • Automatic inlet valve
  • Automatic flush valve
  • Mini PLC controller with display status
  • Chemical dosing system: Anti-scalant
  • PE Pre-filtration Cartridge Housing
  • Cleaning-in-place (CIP) system mounted to frame

Configuration:

  • Single Pass
  • Double Pass

Operating Parameters:

  • Recovery: 50-80%
  • Temperature: 5-35 degrees C
  • Minimum inlet pressure: 2 bar
  • Rejection rate: 95-98%

Application:

  • Boiler water heating
  • Drinking water
  • Pretreatment polishing (such as EDI/Mixed Bed)
  • Industrial applications where low dissolved solids solutions are required
  • Textile
  • Steel mills
  • Pharmaceutical
  • Residential
  • Water recycling

Instrumentation:

  • Pre Cartridge Filtration, Post Cartridge Filtration, membrane inlet and outlet, and Concentrate Pressure gauge.
  • Conductivity / TDS product
  • Low Pressure alarm
  • High Pressure Alarms
  • Flow Indicator (Rotameter): Product and Concentrate
  • Autoflush valve: Diaphragm valve
  • Automatic feed valve: Diaphragm valve

Materials of Construction:

  • Membrane Housing: FRP (Fiber Reinforced Plastics) 300 Psi
  • Frame: Epoxy coated mild steel
  • Permeate and Feed Piping: PVC AW
  • High Pressure Piping: Stainless Steel 304 Sch 20

SW 4-3E to SW 4-12E

Optional Features (Quoted Separately):

  • Stainless Steel Frame
  • Stainless steel piping for permeate and concentrate
  • Remote monitoring system with built-in web-based modem
  • 4-20mA output or other communication for external monitoring
  • Additional chemical dosing system
  • ORP monitoring system
  • Butterfly valve system

Seawater Reverse Osmosis 1–100 m³/h

SW 8-4E hingga SW 8-160E

SW 8-4E to SW 8-160E Capacity: 1 m3/h to 100 m3/h (per unit)

Standard Features:

  • High pressure SWRO Multi Stage Pump
  • 5 micron cartridge filter
  • AW PVC for low pressure piping
  • Stainless steel High pressure piping
  • Automatic valve
  • Automatic flush valve
  • Mini PLC controller with status display
  • Chemical dosing system: Anti-scalant
  • Cleaning-in-place (CIP) system

Specifications:

ModelMembrane QtyPermeate FlowrateFeed FlowrateFlowrate Conc.Pipe Size FeedPipe Size PermeatePipe Size Conc.Frame SizeL (mm)W(mm)H (mm)Power (KW)
BW 8-8 E857.12.11.51.514-25350152012507.5
BW 8-12 E121014.34.321.51.54-353501520165011
BW 8-20 E201521.46.42.52.51.54-553501520220015
BW 8-25 E252028.68.62.52.51.55-563501520220018.5
BW 8-30 E302535.710.732.51.55-4263501870220022
BW 8-35 E353042.912.932.51.55-4363501870185030
BW 8-40 E403550154325-5463501870220037
BW 8-45 E454057.117.14325-5463501870220045
BW 8-50 E504564.319.3432.55-5563501870220055
BW 8-55 E555071.421.4432.56-5573501870220055
BW 8-60 E605578.623.6432.56-5573501870220065
BW 8-66 E666085.725.7432.56-6673501870220075
BW 8-72 E726592.927.9532.56-6673501870220075
BW 8-78 E787010030532.56-55373502220220075
BW 8-84 E8475107.132.16336-55473502220220090
BW 8-90 E9080114.334.36336-55473502220255090
BW 8-96 E9685121.436.46336-55573502220255090
BW 8-102 E10295135.740.76336-66573502220255090
BW 8-108 E108100142.942.96336-666735022202550110

Operation Parameters:

  • Recovery: 50-80%
  • Temperature: 5-35 degrees C
  • Minimum inlet pressure: 2 bar
  • Rejection rate: 95-98%

Applications:

  • Boiler water heater
  • Fresh water systems
  • Industrial water treatment
  • Power plants
  • Steel mills
  • Pharmaceutical
  • Housing
  • Seawater treatment

Configuration:

  • Single Pass
  • Double Pass

Instrumentation:

  • Pre Cartridge Filtration, Post Cartridge Filtration, membrane inlet and outlet, and Concentrate Pressure gauge.
  • Conductivity / TDS product
  • Low Pressure alarm
  • High Pressure Alarms
  • Flow Indicator (Rotameter): Product and Concentrate
  • Autoflush valve: Diaphragm valve / Ball valve

SW 8-4E hingga SW 8-160E

Materials of Construction:

  • Membrane Housing: FRP (Fiber Reinforced Plastics) 300 Psi
  • Frame: Epoxy coated mild steel
  • Permeate and Feed Piping: PVC AW
  • High Pressure Piping: Stainless Steel 316 Sch 40

Brackish Water Reverse Osmosis 0.2–6 m³/h

BW 4-1E to BW 4-24E Capacity: 0.2 m3/h to 6 m3/h (per unit)

SW 8-4E hingga SW 8-160E

Standard Features:

  • Multi Stage Pump
  • 5 micron cartridge filter
  • Stainless steel high pressure piping
  • Automatic flush valve
  • CIP (Clean-in-Place) system
  • Mini PLC controller with status display
  • Anti-scalant dosing system
  • PE cartridge housing for pre-filtration
ModelMembrane QtyPermeate FlowrateFeed FlowrateFlowrate Conc.Pipe Size FeedPipe Size PermeatePipe Size Conc.Frame SizeL (mm)L’ (mm)W(mm)H (mm)H’ (mm)Power (KW)
BW 4-1 E10,1751,21,0250,50,50,5110001250600178011001
BW 4-2 E20,361,41,040,50,50,5110001250600178011001,1
BW 4-3 E30,551,61,0510,50,5110001250600178011001,3
BW 4-4 E40,721,70,9810,50,5110001250600178011001,3
BW 4-6 E61,120,910,50,5110001250600178011001,6
BW 4-8 E81,452,40,9510,750,51 / (3-4)10001250600178011002
BW 4-9 E91,63,21,610,750,51 / (3-3)10001250600178011002,5
BW 4-12 E122,24,11,910,750,753-410001250600178011003,2
BW 4-15 E152,7552,251,5113-32400012501000155011004,75
BW 4-18 E183,256,62,751113-33400012501000155011005,5
BW 4-21 E213,86,62,81,5113-43400012501000155011005,5
BW 4-24 E244,358,13,751,5113-44400012501000155011006,5

Operation Parameter:

  • Recovery: 50-80%
  • Temperature: 5-35 degrees C
  • Minimum inlet pressure: 2 bar
  • Rejection rate: 95-98%

Applications:

  • Boiler water heating
  • Drinking water
  • Industrial water treatment
  • Textile mills
  • Pharmaceutical
  • Housing
  • Water reuse

Configuration:

  • Single Pass
  • Double Pass

Instrumentation:

  • Pre-cartridge filtration, post cartridge filtration, membrane inlet and outlet and concentrate pressure gauge.
  • Conductivity / TDS product
  • Low pressure alarms
  • High pressure alarms
  • Flow indicator (rotameter): product and concentrate
  • Autoflush valve: diaphragm valve
  • Automatic feed valve: diaphragm valve

SW 8-4E hingga SW 8-160E

Materials of Construction:

  • Membrane Housing: FRP (Fibber Reinforced Plastics) 300 Psi
  • Frame: Epoxy coated mild steel
  • Permeate and Feed Piping: PVC AW
  • High Pressure Piping: Stainless Steel 304 Sch 20

Optional Features (Quoted Separately):

  • Stainless steel frame
  • Remote monitoring system
  • Additional chemical dosing system
  • ORP monitoring system
  • Butterfly valve system

Brackish Water Reverse Osmosis 5–100 m³/h

BW 8-8E to BW 8-108E Capacity: 5 m3/h to 100 m3/h (per unit)

Standard Features:

  • Multi-stage pump
  • 5 micron cartridge filter
  • Stainless steel for high pressure piping
  • Automatic flush valve
  • Mini PLC controller with status display
  • Anti-scalant dosing system
  • Cleaning-in-place (CIP) system
ModelMembrane QtyPermeate FlowrateFeed FlowrateFlowrate Conc.Pipe Size FeedPipe Size PermeatePipe Size Conc.Frame SizeL (mm)W(mm)H (mm)Power (KW)
BW 8-8 E857,12,11,51,514-25350152012507,5
BW 8-12 E121014,34,321,51,54-353501520165011
BW 8-20 E201521,46,42,52,51,54-553501520220015
BW 8-25 E252028,68,62,52,51,55-563501520220018,5
BW 8-30 E302535,710,732,51,55-4263501870220022
BW 8-35 E353042,912,932,51,55-4363501870185030
BW 8-40 E403550154325-5463501870220037
BW 8-45 E454057,117,14325-5463501870220045
BW 8-50 E504564,319,3432,55-5563501870220055
BW 8-55 E555071,421,4432,56-5573501870220055
BW 8-60 E605578,623,6432,56-5573501870220065
BW 8-66 E666085,725,7432,56-6673501870220075
BW 8-72 E726592,927,9532,56-6673501870220075
BW 8-78 E787010030532,56-55373502220220075
BW 8-84 E8475107,132,16336-55473502220220090
BW 8-90 E9080114,334,36336-55473502220255090
BW 8-96 E9685121,436,46336-55573502220255090
BW 8-102 E10295135,740,76336-66573502220255090
BW 8-108 E108100142,942,96336-666735022202550110

Operation Parameters:

  • Recovery: 50-80%
  • Temperature: 5-35 degrees C
  • Minimum inlet pressure: 2 bar
  • Rejection rate: 95-98%

Configuration:

  • Single Pass
  • Double Pass

Materials of Construction:

  • Membrane Housing: FRP (Fiber Reinforced Plastics) 300 Psi
  • Frame: Epoxy coated mild steel
  • Permeate and Feed Piping: PVC AW
  • High Pressure Piping: Stainless Steel 304 Sch 20

configuration membrane

Application:

  • Boiler water heating
  • Fresh water treatment
  • Textile mills
  • Pharmaceutical industry
  • Industrial water treatment
  • Power plant

Learn more

Use the industrial reverse osmosis application guide to prepare feedwater analysis, permeate targets, the recovery balance, pretreatment, and a concentrate route before requesting a system proposal.

When RO is being evaluated for reuse, start with the water-conservation guide for communities and industry so the opportunity follows the water balance and the quality required for the next use.

FAQ

What is the difference between BWRO and SWRO systems?

BWRO is intended for brackish water or raw water with lower salinity, while SWRO treats seawater and requires different pressure, energy, pretreatment, materials, and concentrate evaluation. Final selection must follow the feedwater analysis and permeate target.

Is nominal capacity enough to select an industrial RO system?

No. Read permeate capacity with operating hours, recovery, feed and concentrate flow, water quality, fouling or scaling risk, temperature, train count, and the capacity available during cleaning or maintenance.

What data is needed for an industrial RO proposal?

Provide a complete water analysis, source and temperature, permeate flow, operating hours, quality target, concentrate route, power conditions, available space, existing pretreatment, redundancy needs, and the installation and commissioning boundary.